You searched for "leuze Data overdracht"
-
MLD530-R4MType: 4; IEC/EN 61496; SIL: 3; IEC 61508; Performance Level (PL): e; EN ISO 13849-1; Category: 4; EN ISO 13849; Number of beams: 4 Piece(s); Beam spacing: 300mm; Response time: 50 ms; Connection: Connector; M12; Metal; 8Read morePrices available after login
-
Prices available after login
-
BT 21Suitable for: BCL 2x series bar code readers; Fastening; at system: Mounting thread; Mounting bracket; at device: insertable; Material: MetalPrices available after login
-
ISS 218MM/4NO-20N-S12Typ. operating range limit Sn: 20mm; Operating range Sa: 0-16.2mm; Supply voltage: 10-30VDC; Digital switching outputs: 1 Piece(s); Switching output 1: Transistor; PNP; NO (normally open); Switching frequency: 500 Hz; CoRead morePrices available after login
-
LSS 96M-180W-44Operating range limit: 0-39 m; Light source: LED; Red; Interface: AS-Interface IO; Connection: Connector; M12; Metal; 4 -pin; Design; housing: Cubic; Dimensions: 30x90x70mm; Housing material: Metal; Ambient temperature; Read morePrices available after login
-
MLD530-RT2Type: 4; IEC/EN 61496; SIL: 3; IEC 61508; Performance Level (PL): e; EN ISO 13849-1; Category: 4; EN ISO 13849; Operating range: 0.5-8 m; Number of beams: 2 Piece(s); Beam spacing: 500mm; Response time: 50 ms; ConnectionRead morePrices available after login
-
PRK 55/6.002,200-S12Application: Radiation through transparent; colored glass and PET containers; Special design: Autocollimation; Teach input; All stainless steel housing; Operating range limit: 0-5 m; Light source: LED; Red; Supply voltagRead morePrices available after login
-
CB-M12-25000S-5WFConnection 1: Connector; M12; Angled; Female; A-coded; 5 -pin; Connection 2: Open end; Shielded: Yes; Cable length: 25.000mm; Sheathing material: PURPrices available after login
-
Prices available after login
-
Prices available after login
-
MMS-A-2N55Suitable for: PRK retro-reflective photoelectric sensors; HRT diffuse reflection sensors; Design of mounting device: Mounting system; Fastening; at system: Through-hole mounting; Mounting bracket; at device: Groove mountRead morePrices available after login
-
BTU 200M-D12Suitable for: 3B series sensors; 18 series sensors; 25B series sensors; 25C series sensors; 28 series sensors; 3C series sensors; 5 series sensors; 55 series sensors; Design of mounting device: Mounting system; FasteningRead morePrices available after login
-
HRTU 412/4NO.2-S-S12Special design: Teach input; Operating range: 0.01-0.2 m; Direction of beam: Front; Supply voltage: 12-30VDC; Digital switching outputs: 1 Piece(s); Switching output 1: Transistor; PNP; NO (normally open); Switching freqRead morePrices available after login
-
L100-P3C3-M20-MLM24Series: L100; Functions: Locking device with guard interlocking according to ISO 14119; Electro-magnetic guard interlocking (magnet-force); Integration in control circuits up to category 4 in accordance with EN ISO 13849Read morePrices available after login
-
L100-P4C3-M20-SLM24Series: L100; Functions: Locking device with guard interlocking according to ISO 14119; Auxiliary release; Integration in control circuits up to category 4 in accordance with EN ISO 13849-1; Mechanical guard interlockingRead morePrices available after login
-
ODSL 96B M/C66-S12Scanning system: Against object; Light source: Laser; Red; Light spot size: 7x7mm; Measurement range: 300-10.000mm; Geometric resolution: 3.0mm; Accuracy: 0.5 %; Supply voltage: 18-30VDC; Analog outputs: 1 Piece(s); DigiRead morePrices available after login
-
AMS 335i 40Pre-mounted with: Mounting plate; Light source: Laser; Protection class: 2; Measurement range: 200-40.000mm; Absolute measurement accuracy: 2mm; Reproducibility (3 sigma): 0.9mm; Max. traverse rate: 10 m/s; Supply voltagRead morePrices available after login
-
MLD500-T1LSpecial design: Integrated laser alignment aid; Type: 4; IEC/EN 61496; SIL: 3; IEC 61508; Performance Level (PL): e; EN ISO 13849-1:2008; Category: 4; EN ISO 13849:2008; Operating range: 0.5-70 m; Light source: LED; InfrRead morePrices available after login
-
MLD510-R1LType: 4; IEC/EN 61496; SIL: 3; IEC 61508; Performance Level (PL): e; EN ISO 13849-1:2008; Category: 4; EN ISO 13849; Response time: 25 ms; Supply voltage: 24 V; DC; -20-20 %; Connection: Connector; M12; Metal; 5 -pin; DeRead morePrices available after login
-
MLDSET-M1-1300TType: 4; IEC/EN 61496; SIL: 3; IEC 61508; Performance level (PL): e; EN ISO 13849-1; Operating range: 0-8 m; Number of beams: 2 Piece(s); Beam spacing: 500mm; Muting sensors: 2 Piece(s); PRK 25B retro-reflective photoeleRead morePrices available after login
-
PRK 55/6D.42,200-S12Application: Detection of highly transparent bottles; Special design: Autocollimation; Teach input; All stainless steel housing; Operating range limit: 0-3.5 m; Light source: LED; Red; Supply voltage: 10-30VDC; Digital sRead morePrices available after login
-
S-M12A-ETSuitable for interface: Ethernet; Connection: Connector; M12; Axial; Male; D-coded; 4 -pinPrices available after login